Location: Home >> tyco/Eagle Breathing apparatus
>> Air Line
CG-1¡¢CG-1A Airline

CG-1A |

Emergency Kit |
CG-1 and CG-1A are also called Powered Air Respirators.
They are required in relatively fixed places. It mainly
contains cylinder assembly, airline hose, regular assembly,
Facepiece, mobile air cart and 2L carbon fiber escape
cylinder.
 |
| CG-1ÐÍ |
When using the airline, people feel relaxed without
the heavy load, and it is convenient for them to enter
narrow space, like pipes or deep wells, etc. The air
is provided by the cylinder in the cart, which can be
replaced when used up. Thus, the cylinders can provide
air continuously during the rescue. The airline can
reach 70 meters for one single man, and 50 meters for
two men. The Facepiece and regulator are the same with
those for E.RPP positive pressure breathing apparatus.
When the compressed air is almost empty, the alarm will
be activated and inform the supervisor to change cylinder.
When in emergency, open the emergency cylinder valve,
cut off the connector with airline and escape. The emergency
cylinder can provide air for about 10 min.
Technical Data
|
CG-1 |
CG-1A |
| Cylinder |
Water volume |
(L) |
9 |
6 |
6.8 |
9 |
| Material |
|
Carbon fiber cylinder |
Steel cylinder |
Carbon fiber cylinder |
| Operating pressure |
(MPa) |
30 |
| Quantity |
(set) |
2 |
4 |
| Emergency cylinder |
Water volume |
(L) |
2 |
| Material |
|
Carbon fiber cylinder |
| Operating pressure |
(MPa) |
30 |
| Quantity |
(set) |
2 |
| Pressure reducer |
Input pressure |
(MPa) |
¡Ü 30 |
| Output pressure |
(MPa) |
0.7 ¡À
0.02 |
| Rated outlet flow |
(L/min) |
¡Ý 600 |
| Safety valve |
Working pressure |
(MPa) |
¡Ü1.5 open£¬¡Ý 0.84 close
|
| Alarm whistle |
Alarm pressure |
(MPa) |
5.5 ¡À 0.5
|
| Regulator |
Exhale resistance |
(Pa) |
< 870 |
| Hose |
Lengthen |
(m) |
30m /1
hose£¬20m/ 2 hoses |
| Whole set |
Dimension |
(mm) |
998¡Á600¡Á720 |
998¡Á600¡Á935
|
| Weight(charged) |
(kg) |
80 |
122 |
98 |
101 |

|